EPS/TSDCR Regenerative DC Load System 60kW-2,6MW

EPS/TSDCR Regenerative DC Load System 60kW-2,6MW Source - Sink - Battery Charger/Tester/Simulator - Inverter - up to 2.6MW from EPS Stromversorgung

The EPS/TSDCR calibrated test systems from EPS Power Supply are suitable for development-related tests, such as tests of electric drives and fuel cells and their corresponding components, batteries (discharging/charging) and switches. The power ratings go up to 650kW (in parallel connection) in a voltage range from 5 to 1500V and a current range up to 1200A.

The special feature of these systems is that the electrical energy absorbed in generator mode is fed back into the power supply grid with high efficiency. External loads (resistors) are therefore superfluous and electrical energy that would otherwise be "wasted" can be fed back profitably. This regenerative capability is a decisive factor in most test applications, as unusually high power levels are used here.

To increase performance, either parallel connection (up to 4800A/2.6MW) or a multi-channel system (up to 9600A) is possible. In contrast to conventional DC sources, the multi-channel system has two or four independently usable output channels and can operate both as a source and as a sink.

All systems have an electrically isolated output and a TFT touch panel for entering or displaying values and alarms. They can also be controlled via CAN, MODbus TCP (Ethernet), VNC and optionally via HighSpeed/Analog, HighSpeed CAN, Profibus, Profinet and Ethercat. Programming languages are optional: LabView, MatlabSimulink and SCPI.

The system can be freely programmed and has specific algorithms that enable a wide range of tests such as battery tests, testing of fuel cells and solar systems (inverter option), DC electric motors, supercapacitors and power factor correction.

Extensive protective measures, such as an integrated event memory and safety control (level "d") as standard, round off the concept. The system can be "upgraded" to customer specifications, e.g. with insulation monitoring, protective diode for safe sink operation, DC contactors for disconnection under load, power distributor, energy meter or water cooling (IP54, incl. at 300/600kW).
The systems are CE-certified and can optionally be adapted to UL.

Further options on request, as well as higher voltages and currents.

Energy efficiency: New technology, high efficiency regenerative power supply with over 93%

Scope of delivery:
Testsystem
Calibration protocol
Operation manual
EPS/TSDCR 40006001000 Regenerative DC Load System
Order code: 300042
Input Power: 400 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 400 kW
Voltage: 5-600 V DC
Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 40008001000 Regenerative DC Load System
Order code: 300043
Input Power: 400 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 400 kW
Voltage: 5-800 V DC
Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-BusTCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 40010000600 Regenerative DC Load System
Order code: 300044
Input Power: 400 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 400 kW
Voltage: 5-1000 V DC
Current: 0 to ±600 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 400100001000 Regenerative DC Load System
Order code: 300045
Input Power: 400 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 400 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 50006001000 Regenerative DC Load System
Order code: 300047
Input Power: 500 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 400 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 50008001000 Regenerative DC Load System
Order code: 300048
Input Power: 500 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Power: 500 kW
Voltage: 5-800 V DC
Current: 0 to ±1000 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-BusTCP-IP, VNC
Weight: appr. 650 + 1040 = 1690 kg total

EPS/TSDCR 50010000600 Regenerative DC Load System
Order code: 300049
Input Power: 500 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Power: 500 kW
Voltage: 5-1000 V DC
Current: 0 to ±600 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 650 + 1040 = 1690 kg total

EPS/TSDCR 50010001000 Regenerative DC Load System
Order code: 300050
Input Power: 500 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Power: 500 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: 1900+650+900 kg

EPS/TSDCR 65010001000 Regenerative DC Load System
Order code: 300052
Input Power: 650 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Power: 650 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim. Cabinet 1: 1600 w x 800 d x 2200 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2200 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2200 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: 1900+650+900 kg

EPS/TSDCR 03500801000 Regenerative DC Load System
Order code: 300060
Input Power: 35 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 35 kW
Voltage: 5-80 V DC
Current: 0 to ±1000 A
Dim.: 1000 w x 800 d x 1800 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC

EPS/TSDCR 06003000600 Regenerative DC Load System
Order code: 300001
Input Power: 60 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 60 kW
Voltage: 5-300 V DC
Current: 0 to ±600 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC

EPS/TSDCR 06003001000 Regenerative DC Load System
Order code: 300002
Input Power: 60 kW
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 60 kW
Voltage: 5-300 V DC
Current: 0 to ±1000 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC