EPS/TSDCR Regenerative bidirectional Testsystems 60kW-2,6 MW

EPS/TSDCR Regenerative bidirectional Testsystems 60kW-2,6 MW Source - Sink - Battery Charger/Tester/Simulator - Inverter - up to 2,6MW/kVA from EPS Stromversorgung

The calibrated EPS/TSDCR test systems from EPS Power Supply are suitable for development-related tests, such as real-time simulation of the vehicle electrical system, simulation of energy storage systems (e.g. LiIon battery simulation), tests of electric drives and fuel cells and their corresponding components, such as inverters, batteries (charging and discharging) and switches. The power range goes up to 650kW in a voltage range from 5 to 1500V and a current range up to 1200A.
For battery tests, the following special conditions also exist. Step cut-off conditions - time, ET, EV, EC, CC time, CV time, mAh, Wh, SOC, cap (%), cap drop, total mAh, total Wh, last mAh, last SOC, last cap (%), last cap drop, last voltage drop DV, +dV/dt, dV/dt, +dT/dt, CB ,ET, CB EH, EXT ET, SBS ET, cell ET, cell EV.

The special feature of these systems is that the electrical energy consumed in generator mode is fed back into the power supply grid with high efficiency. External loads (resistors) are therefore superfluous and electrical energy that would otherwise be "wasted" can be fed back profitably. This regenerative capability is a decisive factor in most test applications, as unusually high power levels are used here.

To increase performance, either a parallel connection (up to 4800A/2,6MW) or a multi-channel system (up to 9600A) is possible. In contrast to conventional DC sources, the multi-channel system has two or four independently usable output channels and can operate as both a source and a sink.

All systems have an electrically isolated output and a TFT touch panel for entering or displaying values and alarms. They can also be controlled via CAN, MODbus TCP, Ethernet, VNC and optionally via HighSpeed/Analog, HighSpeed CAN, Profibus, Profinet and Ethercat. Programming languages are optional: LabView, MatlabSimulink and SCPI.

The system can be freely programmed and has specific algorithms that enable a wide range of tests such as testing solar systems (inverter option), supercapacitors and power factor correction.
Extensive protective measures, such as a standard integrated event memory and a safety controller (level "d") round off the concept.
The system can be "upgraded" according to customer requirements, e.g. with insulation monitoring, DC contactors for disconnection under load (Standard 300/600kW), an additional discharge unit in the event of a power failure (simulator mode), a power distribution unit (PDU), impedance measurement (tester mode) or water cooling (IP54).

The systems are CE-certified and can optionally be adapted in accordance with UL.

Further options on request.

Energy efficiency: New technology, high efficiency regenerative power supply with over 93%

Scope of delivery:
Testsystem
Calibration protocol
Operation manual

EPS/TSDCR 40006001000 Bidirectional Testsystem Power feedback
Order code: 200542
Voltage:  5-600 VDC
Current:  +- 1000 A
Input Power: 422 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 400 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 40008001000 Bidirectional Testsystem Power feedback
Order code: 200543
Voltage:  5-800 VDC
Current:  +- 1000 A
Input Power: 423 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 400 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 40010000600 Bidirectional Testsystem Power feedback
Order code: 200544
Voltage:  5-1000 VDC
Current:  +- 600 A
Input Power: 422 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 400 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±600 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 40010001000 Bidirectional Testsystem Power feedback
Order code: 200545
Voltage:  5-1000 VDC
Current:  +- 1000 A
Input Power: 425 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 400 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: 1540+770+1150 kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 50006001000 Bidirectional Testsystem Power feedback
Order code: 200547
Voltage:  5-600 VDC
Current:  +- 1000 A
Input Power: 526 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 500 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 50008001000 Bidirectional Testsystem with Power feedback
Order code: 200548
Voltage:  5-800 VDC
Current:  +- 1000 A
Input Power: 526 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Nominal Power: 500 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±1000 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 650 + 1040 = 1690 kg total

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 50010000600 Bidirectional Testsystem with Power feedback
Order code: 200549
Voltage:  5-1000 VDC
Current:  +- 600 A
Input Power: 528 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Nominal Power: 500 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±600 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 650 + 1040 = 1690 kg total

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 50010001000 Bidirectional Testsystem with Power feedback
Order code: 200550
Voltage:  5-1000 VDC
Current:  +- 1000 A
Input Power: 528 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Nominal Power: 500 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±1000 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: 1900+800+1150 kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 65010001000 Bidirectional Testsystem with Power feedback
Order code: 200552
Voltage:  5-1000 VDC
Current:  +- 1000 A
Input Power: 681 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Nominal Power: 650 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±1000 A
Dim. Cabinet 1: 1600 w x 800 d x 2200 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2200 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2200 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: 1900+650+900 kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 06006001000 Bidirectional Testsystem Power feedback
Order code: 200504
Voltage:  5-600 VDC
Current:  +- 1000 A
Input Power: 70 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 60 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±1000 A
Dim.: 1000 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 65012001200 Bidirectional Testsystem with Power feedback
Order code: 200553
Voltage:  10-1200 VDC
Current:  +- 1200 A
Input Power: 687 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Nominal Power: 650 kW
Output Voltage: 10-1200 V DC
Output Current: 0 to ±1200 A
Dim. Cabinet 1: 1600 w x 800 d x 2200 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2200 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2200 h mm
(incl. Socket 200 h mm)
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: 2300+900+1150 kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 60015001000 Bidirectional Testsystem Power feedback
Order code: 200551
Voltage:  10-1500 VDC
Current:  +- 1000 A
Power: 600000 W
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 600 kW
Output Voltage: 10-1500 V DC
Voltage with center point
Output Current: 0 to ±1000 A
Dim.: 4x 1200 w x 800 d x 2200 h mm
incl. 200 mm socket and cooling unit
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: separate cooling circuit with
water/water heat exchanger
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Incl. 2x ISO monitoring (can be switched separately)
Interface: CAN, MOD-Bus,TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095