Filter

  - 

Current

A   -   A

Voltage

V   -   V

Power

W   -   W

Design

Operating Characteristic



Categories

EPS/TSDCR Regenerative bidirectional Testsystems 60kW-2,6 MW

EPS/TSDCR Regenerative bidirectional Testsystems 60kW-2,6 MW Source - Sink - Battery Charger/Tester/Simulator - Inverter - up to 2,6MW/kVA from EPS Stromversorgung

The calibrated EPS/TSDCR test systems from EPS Power Supply are suitable for development-related tests, such as real-time simulation of the vehicle electrical system, simulation of energy storage systems (e.g. LiIon battery simulation), tests of electric drives and fuel cells and their corresponding components, such as inverters, batteries (charging and discharging) and switches. The power range goes up to 650kW in a voltage range from 5 to 1500V and a current range up to 1200A.
For battery tests, the following special conditions also exist. Step cut-off conditions - time, ET, EV, EC, CC time, CV time, mAh, Wh, SOC, cap (%), cap drop, total mAh, total Wh, last mAh, last SOC, last cap (%), last cap drop, last voltage drop DV, +dV/dt, dV/dt, +dT/dt, CB ,ET, CB EH, EXT ET, SBS ET, cell ET, cell EV.

The special feature of these systems is that the electrical energy consumed in generator mode is fed back into the power supply grid with high efficiency. External loads (resistors) are therefore superfluous and electrical energy that would otherwise be "wasted" can be fed back profitably. This regenerative capability is a decisive factor in most test applications, as unusually high power levels are used here.

To increase performance, either a parallel connection (up to 4800A/2,6MW) or a multi-channel system (up to 9600A) is possible. In contrast to conventional DC sources, the multi-channel system has two or four independently usable output channels and can operate as both a source and a sink.

All systems have an electrically isolated output and a TFT touch panel for entering or displaying values and alarms. They can also be controlled via CAN, MODbus TCP, Ethernet, VNC and optionally via HighSpeed/Analog, HighSpeed CAN, Profibus, Profinet and Ethercat. Programming languages are optional: LabView, MatlabSimulink and SCPI.

The system can be freely programmed and has specific algorithms that enable a wide range of tests such as testing solar systems (inverter option), supercapacitors and power factor correction.
Extensive protective measures, such as a standard integrated event memory and a safety controller (level "d") round off the concept.
The system can be "upgraded" according to customer requirements, e.g. with insulation monitoring, DC contactors for disconnection under load (Standard 300/600kW), an additional discharge unit in the event of a power failure (simulator mode), a power distribution unit (PDU), impedance measurement (tester mode) or water cooling (IP54).

The systems are CE-certified and can optionally be adapted in accordance with UL.

Further options on request.

Energy efficiency: New technology, high efficiency regenerative power supply with over 93%

Scope of delivery:
Testsystem
Calibration protocol
Operation manual

EPS/TSDCR 25006001000 Bidirectional Testsystem Power feedback
Order code: 200528
Voltage:  5-600 VDC
Current:  +- 1000 A
Input Power: 266 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 250 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 25008000600 Bidirectional Testsystem Power feedback
Order code: 200529
Voltage:  5-800 VDC
Current:  +- 600 A
Input Power: 264 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 250 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 25008001000 Bidirectional Testsystem Power feedback
Order code: 200530
Voltage:  5-800 VDC
Current:  +- 1000 A
Input Power: 267 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 250 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 25010000600 Bidirectional Testsystem Power feedback
Order code: 200531
Voltage:  5-1000 VDC
Current:  +- 600 A
Input Power: 266 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 250 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 25010001000 Bidirectional Testsystem Power feedback
Order code: 200532
Voltage:  5-1000 VDC
Current:  +- 1000 A
Input Power: 269 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 250 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 30015001000 Bidirectional Testsystem Power feedback
Order code: 200533
Voltage:  10-1500 VDC
Current:  +- 1000 A
Power: 300000 W
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 300 kW
Output Voltage: 10-1500 V DC
Voltage with center point
Output Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
incl. 200 mm socket and cooling unit
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: separate cooling circuit with
water/water heat exchanger
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Incl. 2x ISO monitoring (can be switched separately)
Interface: CAN, MOD-Bus,TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32003001000 Bidirectional Testsystem Power feedback
Order code: 200535
Voltage:  5-600 VDC
Current:  +- 1000 A
Input Power: 339 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 320 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32008000600 Bidirectional Testsystem Power feedback
Order code: 200536
Voltage:  5-800 VDC
Current:  +- 600 A
Input Power: 337 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 320 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32008001000 Bidirectional Testsystem Power feedback
Order code: 200537
Voltage:  5-800 VDC
Current:  +- 1000 A
Input Power: 340 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 320 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32010000600 Bidirectional Testsystem Power feedback
Order code: 200538
Voltage:  5-1000 VDC
Current:  +- 600 A
Input Power: 338 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 320 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32010001000 Bidirectional Testsystem Power feedback
Order code: 200539
Voltage:  5-1000 VDC
Current:  +- 1000 A
Input Power: 342 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 320 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 32012000600 Bidirectional Testsystem Power feedback
Order code: 200540
Voltage:  10-1200 VDC
Current:  +- 600 A
Input Power: 342 kVA
Design: Cabinet
Operating Characteristic: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 320 kW
Output Voltage: 10-1200 V DC
Output Current: 0 to ±600 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095