Filter
Categories
EPS/HC 4000-M DC Current Source up to 48 kW
![EPS/HC 4000-M DC Current Source up to 48 kW](https://www.eps-germany.de/shop/images/categories/a2522_0.jpg)
All units are short-circuit proofed and overload protected. Moreover, your DUT is protected against overvoltage (OVP) and overcurrent (OCP).
The heavy duty switch mode power stage is build in a compact build-in housing in 4 different form factors (M1, M2, M3, M4) .
The modules are by standard without control.
The power modules can be controlled via the optional, external and comfortable LCD user panel »EPS/HC280«.
Optionally analog and digital interfaces (modules) for RS485, Profibus and USB-Adapter (on analog) are available to control all the functions via a PC. The DC sources with high output current are available with Cu bars and with high output voltage with HDFK terminals.
Remote sensing can be optionally done via a dedicated input which is directly connected to the test equipment, in order to compensate for voltage drops on the lines.
Energy Efficiency: High efficiency
Scope of delivery:
Power Supply
Brackets (Design M3, M4)
Operation Manual
EPS/HC 40030-600-M DC Current Source
Order code: 200960
Voltage: 0-30 VDC
Current: 0-600 A
Power: 18000 W
Design: Built-in
Voltage: 0-30 VDC
Current: 0-600 A
Power: 18000 W
Design: Built-in
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-30VDC
Output Current: 0-600 A
Output Power: 18000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455
Total Depth: 627mm
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-600 A
Output Power: 18000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455
Total Depth: 627mm
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40030-1200-M DC Current Source
Order code: 200961
Voltage: 0-30 VDC
Current: 0-1200 A
Power: 36000 W
Design: Built-in
Voltage: 0-30 VDC
Current: 0-1200 A
Power: 36000 W
Design: Built-in
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-30VDC
Output Current: 0-1200 A
Output Power: 36000 W
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
Enclosure: Stainless steel
max. ambient temperature: 0-40°C
air cooling, volume flow 700-1200m³/h (Front)
Dimensions (WxHxD mm): "Module 4" 413x261x596
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-1200 A
Output Power: 36000 W
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
Enclosure: Stainless steel
max. ambient temperature: 0-40°C
air cooling, volume flow 700-1200m³/h (Front)
Dimensions (WxHxD mm): "Module 4" 413x261x596
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40040-600-M DC Current Source
Order code: 200962
Voltage: 0-40 VDC
Current: 0-600 A
Power: 240000 W
Design: Built-in
Voltage: 0-40 VDC
Current: 0-600 A
Power: 240000 W
Design: Built-in
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-40VDC
Output Current: 0-600A
Output Power: 24000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455
Total Depth: 627mm
Inrush current limmitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-600A
Output Power: 24000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455
Total Depth: 627mm
Inrush current limmitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40040-1200-M DC Current Source
Order code: 200963
Voltage: 0-40 VDC
Current: 0-1200 A
Power: 48000 W
Design: Built-in
Voltage: 0-40 VDC
Current: 0-1200 A
Power: 48000 W
Design: Built-in
Shipping time:
![deliverable upon request deliverable upon request](/shop/images/ampel_rot.png)
Output Voltage: 0-40VDC
Output Current: 0-1200A
Output Power: 48000 W
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
Enclosure: Stainless steel
max. ambient temperature: 0-40°C
air cooling, volume flow 700-1200m³/h (Front)
Dimensions (WxHxD mm): "Module 4" 413x261x596
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-1200A
Output Power: 48000 W
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
Enclosure: Stainless steel
max. ambient temperature: 0-40°C
air cooling, volume flow 700-1200m³/h (Front)
Dimensions (WxHxD mm): "Module 4" 413x261x596
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40050-250-M DC Current Source
Order code: 200964
Voltage: 0-50 VDC
Current: 0-250 A
Power: 12500 W
Design: Tower
Voltage: 0-50 VDC
Current: 0-250 A
Power: 12500 W
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-50 VDC
Output Current: 0-250 A
Output Power: 12500 W
Enclosure: Stainless steel IP20 (fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 500m3/h (Front)
Dimensions (WxHxD mm): 19"-Module 3, 314x262x455
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Total depth: 627mm
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504 4082
Output Current: 0-250 A
Output Power: 12500 W
Enclosure: Stainless steel IP20 (fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 500m3/h (Front)
Dimensions (WxHxD mm): 19"-Module 3, 314x262x455
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Total depth: 627mm
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504 4082
EPS/HC 40006-600-M DC Current Source
Order code: 200941
Voltage: 0-6 VDC
Current: 0-600 A
Power: 3600 W
Design: Tower
Voltage: 0-6 VDC
Current: 0-600 A
Power: 3600 W
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-6 VDC
Output Current: 0-600 A
Output Power: 3600 W
Enclosure: Stainless steel IP20 (fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x100m3/h (Front)
Dimensions (WxHxD mm): Module 2, 212x244,5x400
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-600 A
Output Power: 3600 W
Enclosure: Stainless steel IP20 (fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x100m3/h (Front)
Dimensions (WxHxD mm): Module 2, 212x244,5x400
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40006-1000-M DC Current Source
Order code: 200942
Voltage: 0-6 VDC
Current: 0-1000 A
Power: 6000 W
Design: Built-in
Voltage: 0-6 VDC
Current: 0-1000 A
Power: 6000 W
Design: Built-in
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-6 VDC
Output Current: 0-1000 A
Output Power: 6000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455(492)
Total Depth: 627mm
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-1000 A
Output Power: 6000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455(492)
Total Depth: 627mm
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40006-2200-M DC Current Source
Order code: 200944
Voltage: 0-6 VDC
Current: 0-2200 A
Power: 13200 W
Design: Built-in
Voltage: 0-6 VDC
Current: 0-2200 A
Power: 13200 W
Design: Built-in
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-6VDC
Output Current: 0-2200 A
Output Power:13200 W
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
Enclosure: Stainless steel
max. ambient temperature: 0-40°C
air cooling, volume flow 700-1200m³/h (Front)
Dimensions (WxHxD mm): "Module 4" 413x261x596
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-2200 A
Output Power:13200 W
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
Enclosure: Stainless steel
max. ambient temperature: 0-40°C
air cooling, volume flow 700-1200m³/h (Front)
Dimensions (WxHxD mm): "Module 4" 413x261x596
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40010-300-M DC Current Source
Order code: 200946
Voltage: 0-10 VDC
Current: 0-300 A
Power: 3000 W
Design: Tower
Voltage: 0-10 VDC
Current: 0-300 A
Power: 3000 W
Design: Tower
Shipping time:
![quickly deliverable quickly deliverable](/shop/images/ampel_gruen.png)
Output Voltage: 0-10 VDC
Output Current: 0-300 A
Output Power: 3000 W
Enclosure: Stainless steel IP20 (fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 100m3/h (Front)
Dimensions (WxHxD mm): Module 1, 106 x 245 x 402
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-300 A
Output Power: 3000 W
Enclosure: Stainless steel IP20 (fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 100m3/h (Front)
Dimensions (WxHxD mm): Module 1, 106 x 245 x 402
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40010-600-M DC Current Source
Order code: 200947
Voltage: 0-10 VDC
Current: 0-600 A
Power: 6000 W
Design: Tower
Voltage: 0-10 VDC
Current: 0-600 A
Power: 6000 W
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-10 VDC
Output Current: 0-600 A
Output Power: 6000 W
Enclosure: Stainless steel IP20 (fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x100m3/h (Front)
Dimensions (WxHxD mm): Module 2, 212x244,5x432
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-600 A
Output Power: 6000 W
Enclosure: Stainless steel IP20 (fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x100m3/h (Front)
Dimensions (WxHxD mm): Module 2, 212x244,5x432
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40010-1000-M DC Current Source
Order code: 200948
Voltage: 0-10 VDC
Current: 0-1000 A
Power: 10000 W
Design: Built-in
Voltage: 0-10 VDC
Current: 0-1000 A
Power: 10000 W
Design: Built-in
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-10VDC
Output Current: 0-1000 A
Output Power: 10000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max.2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455
Total Depth: 627mm
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-1000 A
Output Power: 10000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max.2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455
Total Depth: 627mm
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
EPS/HC 40010-1200-M DC Current Source
Order code: 200949
Voltage: 0-10 VDC
Current: 0-1200 A
Power: 12000 W
Design: Built-in
Voltage: 0-10 VDC
Current: 0-1200 A
Power: 12000 W
Design: Built-in
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0-10VDC
Output Current: 0-1200 A
Output Power: 12000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455
Total Depth: 627mm
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082
Output Current: 0-1200 A
Output Power: 12000 W
Enclosure: Stainless steel IP20 (Fan IP20)
Mains Voltage: 3x400 VAC +-10% 50-60 Hz
max. ambient temperature: 0-40°C
air cooling, volume flow max. 2x240m3/h (Front)
Dimensions (WxHxD mm): "Module 3" 314x262x455
Total Depth: 627mm
Inrush current limitation
Constant Voltage (CV), Constant Current (CC)
Carrying handles front and back
Incl. mounting bracket
Country of origin: Germany
Customs tariff code: 8504.4082