Filter

  - 

Current

A   -   A

Voltage

V   -   V

Power

W   -   W

Design

Behavior



All products

EPS/TSDCR 50010000600 Regenerative DC Load System
Order code: 300049
Input Power: 500 kW
Design: Cabinet
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Power: 500 kW
Voltage: 5-1000 V DC
Current: 0 to ±600 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 650 + 1040 = 1690 kg total

EPS/TSDCR 50010001000 Bidirectional Testsystem with Power feedback
Order code: 200550
Voltage:  5-1000 VDC
Current:  +- 1000 A
Input Power: 528 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Nominal Power: 500 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±1000 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: 1900+800+1150 kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 50010001000 Regenerative DC Load System
Order code: 300050
Input Power: 500 kW
Design: Cabinet
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Power: 500 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim. Cabinet 1: 1400 w x 800 d x 2000 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2000 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: 1900+650+900 kg

EPS/TSDCR 60015001000 Bidirectional Testsystem Power feedback
Order code: 200551
Voltage:  10-1500 VDC
Current:  +- 1000 A
Power: 600000 W
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 600 kW
Output Voltage: 10-1500 V DC
Voltage at the centre
Output Current: 0 to ±1000 A
Dim.: 4x 1200 w x 800 d x 2200 h mm
incl. 200 mm socket and cooling unit
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: separate cooling circuit with
water/water heat exchanger
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 65010001000 Bidirectional Testsystem with Power feedback
Order code: 200552
Voltage:  5-1000 VDC
Current:  +- 1000 A
Input Power: 681 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Nominal Power: 650 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±1000 A
Dim. Cabinet 1: 1600 w x 800 d x 2200 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2200 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2200 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: 1900+650+900 kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 65010001000 Regenerative DC Load System
Order code: 300052
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Power: 650 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim. Cabinet 1: 1600 w x 800 d x 2200 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2200 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2200 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: 1900+650+900 kg

EPS/TSDCR 65012001200 Bidirectional Testsystem with Power feedback
Order code: 200553
Voltage:  10-1200 VDC
Current:  +- 1200 A
Input Power: 687 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage: 380/400/440/480/500 VAC ±10%,
3-ph.,PE, 50/60Hz (please state required voltage when ordering)
Nominal Power: 650 kW
Output Voltage: 10-1200 V DC
Output Current: 0 to ±1200 A
Dim. Cabinet 1: 1600 w x 800 d x 2200 h mm
Dim. Cabinet 2: 1200 w x 800 d x 2200 h mm
Dim. Cabinet 3: 1200 w x 800 d x 2200 h mm
(incl. Socket 200 h mm)
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: 2300+900+1150 kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR-MC Multi Channel Basic System
Order code: 124000
Shipping time: deliverable
EPS/ZH 2-Quadrant Module
Order code: 112685
Shipping time: deliverable
Active Load module (für 1/1,5/3 kW models)
build-in the PS, 3 kW models change to 4U size
Peak pulse power: 2400W
Peak pulse current: 200A
Contineous power: 150W