Filter

  - 

Current

A   -   A

Voltage

V   -   V

Power

W   -   W

Design

Behavior



All products

EPS/TSDCR 16008000200 Regenerative DC Load System
Order code: 300021
Input Power: 160 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 160 kW
Voltage: 5-800 V DC
Current: 0 to ±200 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 16008000600 Bidirectional Testsystem Power feedback
Order code: 200522
Voltage:  5-800 VDC
Current:  +- 600 A
Input Power: 171 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 160 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±600 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 16008000600 Regenerative DC Load System
Order code: 300022
Input Power: 160 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 160 kW
Voltage: 5-800 V DC
Current: 0 to ±600 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 16008001000 Bidirectional Testsystem Power feedback
Order code: 200523
Voltage:  5-800 VDC
Current:  +- 1000 A
Input Power: 174 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 160 kW
Output Voltage: 5-800 V DC
Output Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2300 (1150+1150) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 16008001000 Regenerative DC Load System
Order code: 300023
Input Power: 160 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 160 kW
Voltage: 5-800 V DC
Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 16010000200 Bidirectional Testsystem Power feedback
Order code: 200524
Voltage:  5-1000 VDC
Current:  +- 200 A
Input Power: 170 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 160 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±200 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1000 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 16010000200 Regenerative DC Load System
Order code: 300024
Input Power: 160 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 160 kW
Voltage: 5-1000 V DC
Current: 0 to ±200 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 16010000600 Bidirectional Testsystem Power feedback
Order code: 200525
Voltage:  5-1000 VDC
Current:  +- 600 A
Input Power: 172 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 160 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±600 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 16010000600 Regenerative DC Load System
Order code: 300025
Input Power: 160 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 160 kW
Voltage: 5-1000 V DC
Current: 0 to ±600 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 16010001000 Bidirectional Testsystem Power feedback
Order code: 200526
Voltage:  5-1000 VDC
Current:  +- 1000 A
Input Power: 175 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 160 kW
Output Voltage: 5-1000 V DC
Output Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095

EPS/TSDCR 16010001000 Regenerative DC Load System
Order code: 300026
Input Power: 160 kW
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Mains:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Power: 160 kW
Voltage: 5-1000 V DC
Current: 0 to ±1000 A
Dim.: 1200 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: at the front door
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

EPS/TSDCR 25006001000 Bidirectional Testsystem Power feedback
Order code: 200528
Voltage:  5-600 VDC
Current:  +- 1000 A
Input Power: 266 kVA
Design: Cabinet
Behavior: Bidirectional
Shipping time: deliverable
PWM-Technology/transistor controlled
Input Voltage:400 VAC ±10% 3-ph.,PE, 50/60Hz
(please state required voltage when ordering)
Nominal Power: 250 kW
Output Voltage: 5-600 V DC
Output Current: 0 to ±1000 A
Dim.: 1400 w x 800 d x 2000 h mm
and 1200 d x 800 d x 2000 h mm
Display: TFT Touch Panel
AC-connection: Input termination, sidewise at the base
DC-connection: Cupper-bars
Cooling: fans, temperature controlled
Emergency Stop: (Terminal)
Safety control: Performance Level "d"
Protection: OVP, UVP, OCP, OTP
Interface: CAN, MOD-Bus,SCPI/TCP-IP, VNC
Weight: appr. 2150 (1150+1000) kg

Country of origin: Germany
Customs tariff code: 8504.4095