Filter

  - 

Current

A   -   A

Voltage

V   -   V

Power

W   -   W

Design

Behavior



All products

EPS/BT 20360-240 4U Regenerative Battery Tester
Order code: 700024
Voltage:  0-360 VDC
Current:  0-240 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
Output Voltage: 0 V DC - 360 V DC
In-/Output Current: +-0 A - 240 A
Output Power:+-30000 W
Regeneration of the DC power into the
AC grid, efficiency <=95,8%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/BT 20360-80 Triple Regenerative Battery Tester
Order code: 700045
Voltage:  0-360 VDC / 0-360 VDC / 0-360 VDC
Current:  0-80 A / +-80 A / +-80 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
3 Channels
Output Voltage: 0 V DC - 360 V DC
In-/Output Current: +-0 A - 80 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=95,8%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/BT 20500-180 4U Regenerative Battery Tester
Order code: 700025
Voltage:  0-500 VDC
Current:  0-180 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
Output Voltage: 0 V DC - 500 V DC
In-/Output Current: +-0 A - 180 A
Output Power:+-30000 W
Regeneration of the DC power into the
AC grid, efficiency <=96,8%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/BT 20500-60 Triple Regenerative Battery Tester
Order code: 700046
Voltage:  0-500 VDC / 0-500 VDC / 0-500 VDC
Current:  0-60 A / +-60 A / +-60 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
3 Channels
Output Voltage: 0 V DC - 500 V DC
In-/Output Current: +-0 A - 60 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/BT 20920-120 4U Regenerative Battery Tester
Order code: 700026
Voltage:  0-920 VDC
Current:  0-120 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
Output Voltage: 0 V DC - 920 V DC
In-/Output Current: +-0 A - 120 A
Output Power:+-30000 W
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/BT 20920-40 Triple Regenerative Battery Tester
Order code: 700047
Voltage:  0-920 VDC / 0-920 VDC / 0-920 VDC
Current:  0-40 A / +-40 A / +-40 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
3 Channels
Output Voltage: 0 V DC - 920 V DC
In-/Output Current: +-0 A - 40 A/channel
Output Power:+-30000 W (10000W/channel)
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/BT 21000-80 4U Regenerative Battery Tester
Order code: 700027
Voltage:  0-1000 VDC
Current:  0-80 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
Output Voltage: 0 V DC - 1000 V DC
In-/Output Current: +-0 A - 80 A
Output Power:+-30000 W
Regeneration of the DC power into the
AC grid, efficiency <=95,8%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/BT 21500-60 4U Regenerative Battery Tester
Order code: 700028
Voltage:  0-1500 VDC
Current:  0-60 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
Output Voltage: 0 V DC - 1500 V DC
In-/Output Current: +-0 A - 60 A
Output Power:+-30000 W
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/BT 22000-40 4U Regenerative Battery Tester
Order code: 700029
Voltage:  0-2000 VDC
Current:  0-43,75 A
Power: 0-30000 W
Design: 19 inch
Behavior: Bidirectional
Shipping time: deliverable
Output Voltage: 0 V DC - 2000 V DC
In-/Output Current: +-0 A - 40 A
Output Power:+-30000 W
Regeneration of the DC power into the
AC grid, efficiency <=96,5%
Input Voltage: 380V/400V/480V AC +-10% 3ph., 45...65 Hz
(208V-240V AC +-10% derating to 18kW)
Dimensions (WxHxD): 19"x4Ux668mm
2 Quadrant operation
Battery-Simulation
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Series Remote sensing (auto-sensing)
Parallel operation
Interfaces: Ethernet, USB, EtherCAT, CAN FD,
USB Host Front, 3 digital inputs, 3 relay contacts,
3 temperature sensor inputs

Country of origin: Germany
Customs tariff code: 8504.3200

EPS/CSI 1000-110-230 Sine Wave Inverter
Order code: 600011
Voltage:  230 VAC
Current:  7,4A
Power: 1000 VA
Design: Built-in
Shipping time: deliverable
Input DC: 110V
Output Voltage AC: 230V 1ph.
Output frequency: 50 Hz
Output Power: 1000VA
Dimensions (WxHxD): 132x132x407 mm
Chassis design
The output neutral is internally connected
to the chassis

Country of origin: Canada
Customs tariff code: 8504.4095.40

EPS/CSI 1000-125-230 Sine Wave Inverter
Order code: 600012
Voltage:  230 VAC
Current:  4,3A
Power: 1000 VA
Design: Built-in
Shipping time: deliverable
Input DC: 125V
Output Voltage AC: 230V 1ph.
Output frequency: 50 Hz
Output Power: 1000VA
Dimensions (WxHxD): 132x132x407 mm
Chassis design
The output neutral is internally connected
to the chassis

Country of origin: Canada
Customs tariff code: 8504.4095.40

EPS/CSI 1000-24-230 Sine Wave Inverter
Order code: 600009
Voltage:  230 VAC
Current:  4,3A
Power: 1000 VA
Design: Built-in
Shipping time: deliverable
Input DC: 24V
Output Voltage AC: 230V 1ph.
Output frequency: 50 Hz
Output Power: 1000VA
Dimensions (WxHxD): 187x132x407 mm
Chassis design
The output neutral is internally connected
to the chassis

Country of origin: Canada
Customs tariff code: 8504.4095.40