Filter
Categories
All products
E/PSI 9040-40 DT 1kW Laboratory Power Supply
Order code: 200156
Voltage: 0-40 VDC
Current: 0-40 A
Power: 1000 W
Design: Desktop
Voltage: 0-40 VDC
Current: 0-40 A
Power: 1000 W
Design: Desktop
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 40 A
Output Power: 0-1000 W (Safety low voltage <60V)
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 40 A
Output Power: 0-1000 W (Safety low voltage <60V)
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3200
E/PSI 9040-40 DT Laboratory Power Supply
Order code: 200153
Voltage: 0-40 VDC
Current: 0-40 A
Power: 0-640 W
Design: Desktop
Voltage: 0-40 VDC
Current: 0-40 A
Power: 0-640 W
Design: Desktop
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 40 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3121
Output Current: 0 A - 40 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3121
E/PSI 9040-40 T 1000W Laboratory Power Supply
Order code: 200186
Voltage: 0-40 VDC
Current: 0-40 A
Power: 0-1000 W
Design: Tower
Voltage: 0-40 VDC
Current: 0-40 A
Power: 0-1000 W
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x412mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x412mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
E/PSI 9040-40 T 640W Laboratory Power Supply
Order code: 200183
Voltage: 0-40 VDC
Current: 0-40 A
Power: 0-640 W
Design: Tower
Voltage: 0-40 VDC
Current: 0-40 A
Power: 0-640 W
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 40 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x352mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
Output Current: 0 A - 40 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x352mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
E/PSI 9040-60 DT Laboratory Power Supply
Order code: 200162
Voltage: 0-40 VDC
Current: 0-60 A
Power: 1500 W
Design: Desktop
Voltage: 0-40 VDC
Current: 0-60 A
Power: 1500 W
Design: Desktop
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 60 A
Output Power: 0-1500 W (Safety low voltage <60V)
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 60 A
Output Power: 0-1500 W (Safety low voltage <60V)
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3200
E/PSI 9040-60 T Laboratory Power Supply
Order code: 200190
Voltage: 0-40 VDC
Current: 0-60 A
Power: 1500W (1kW derating)
Design: Tower
Voltage: 0-40 VDC
Current: 0-60 A
Power: 1500W (1kW derating)
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 40 VDC
Output Current: 0 A - 60 A
Output Power: 0-1500 W (1000 derating)
Input Voltage: 150-264 VAC, (90-150 VAC derating) 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x412mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 60 A
Output Power: 0-1500 W (1000 derating)
Input Voltage: 150-264 VAC, (90-150 VAC derating) 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x412mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3200
E/PSI 9080-10 DT Laboratory Power Supply
Order code: 200151
Voltage: 0-80 VDC
Current: 0-10 A
Power: 0-320 W
Design: Desktop
Voltage: 0-80 VDC
Current: 0-10 A
Power: 0-320 W
Design: Desktop
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 10 A
Output Power: 0-320 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3121
Output Current: 0 A - 10 A
Output Power: 0-320 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3121
E/PSI 9080-10 T Laboratory Power Supply
Order code: 200181
Voltage: 0-80 VDC
Current: 0-10 A
Power: 0-320 W
Design: Tower
Voltage: 0-80 VDC
Current: 0-10 A
Power: 0-320 W
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 10 A
Output Power: 0-320 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x352mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
Output Current: 0 A - 10 A
Output Power: 0-320 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x352mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
E/PSI 9080-20 DT Laboratory Power Supply
Order code: 200154
Voltage: 0-80 VDC
Current: 0-20 A
Power: 0-640 W
Design: Desktop
Voltage: 0-80 VDC
Current: 0-20 A
Power: 0-640 W
Design: Desktop
Shipping time:
![quickly deliverable quickly deliverable](/shop/images/ampel_gruen.png)
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 20 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3121
Output Current: 0 A - 20 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x355mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3121
E/PSI 9080-20 T Laboratory Power Supply
Order code: 200184
Voltage: 0-80 VDC
Current: 0-20 A
Power: 0-640 W
Design: Tower
Voltage: 0-80 VDC
Current: 0-20 A
Power: 0-640 W
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 20 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x352mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
Output Current: 0 A - 20 A
Output Power: 0-640 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x352mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
E/PSI 9080-40 DT Laboratory Power Supply
Order code: 200157
Voltage: 0-80 VDC
Current: 0-40 A
Power: 0-1000 W
Design: Desktop
Voltage: 0-80 VDC
Current: 0-40 A
Power: 0-1000 W
Design: Desktop
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x415mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3200
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Desktop with carrying handle and tilt stand
Dimensions (WxHxD): 276x103x415mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
Analog Interface, isolated
LAN and USB Interface with LabView VIs
and Software
Country of origin: Germany
Customs tariff code: 8504.3200
E/PSI 9080-40 T Laboratory Power Supply
Order code: 200187
Voltage: 0-80 VDC
Current: 0-40 A
Power: 0-1000 W
Design: Tower
Voltage: 0-80 VDC
Current: 0-40 A
Power: 0-1000 W
Design: Tower
Shipping time:
![deliverable deliverable](/shop/images/ampel_gelb.png)
Output Voltage: 0 VDC - 80 VDC
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x412mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121
Output Current: 0 A - 40 A
Output Power: 0-1000 W
Input Voltage: 90-264 VAC, 1 ph.+N; 50/60 Hz
Dimensions (WxHxD): 92x237x412mm
Integrated Function and Arbitrary Generator
Internal Resistance Simulation
Programmable at the frontside via Touchpanel
Supervision, i.e. OVD, UVD
Protection: OVP, OCP, OPP and OTP
Constant Voltage- (CV) Current (CC) and Power (CP)
Internal resistance regulation (CR)
Remote sensing (auto-sensing)
Parallel operation
Preset of 5 different output values
5 User Profiles
Alarmmanagement
USB Interface with LabView VIs and Software
Country of origin: Germany
Customs tariff code: 8504.3121